Product Notice: Update Screw Tightening Torque for Panel Mount Power Supplies PMT2 and PMR Series


For Delta’s panel mount power supplies PMT2 and PMR Series, the maximum recommended screw tightening torque for mounting holes using M3 screws is 7 kgf.cm (6.08 lbf.in), which is superior to the industrial standard of 5 kgf.cm (4.33 lbf.in) based on the same screw material.


To prevent the use of screws that do not meet industrial standards, potentially causing thread slippage or installation matching issues, Delta has updated the maximum recommended screw tightening torque in the datasheets and manuals from 4~7 kgf.cm (3.47~6.08 lbf.in) to 4~5 kgf.cm (3.47~4.33 lbf.in).


Please refer to the table below for more details. The updated datasheets and manuals are now available on the DeltaPSU website. Should you require any further clarification, please reach out to us via our Contact Us Form.


Change Details:

Product Series Models Change Details
PMT2 PMT-xxV35W2BAx
PMT-xxV50W2BAx
PMT-xxV75W2BAx
PMT-xxV100W2BAx
PMT-xxV150W2BAx/2CAx
PMT-xxV200W2Bx
PMT-xxV350W2Bx
PMT-DxV75W2BAx/2CAx


PMR PMR-xxV150W1AT
PMR-xxV240W1AT
PMR-xxV320W1AT
PMR-xxV600W1BT

Related News

Medical MDS-400ADB24, MEB-750A, MEB-1K5A48T AAA and MEB-1K2A Series Product Change Notice

Delta enhances the stability and provides users with better protection for MDS-400ADB24, M ...

Mehr

Medical MDS-250, MDS-300 and MDS-400 Series Product Change Notice

Control connector (CN 101) from Molex used in MDS-250, MDS-300 and MDS-400 medical power s ...

Mehr

Delta Industrial Power Supply Certificate Upgrade Notice

IEC/UL/EN 60950-1 safety standard will be replaced by IEC/UL/EN 62368-1 on December 20th, ...

Mehr

Melden Sie sich jetzt für unseren Newsletter an

Seien Sie mit der/die erste um über neue Veranstaltungen, Neuigkeiten und Produkte informiert zu werden!

Melden Sie sich jetzt für unseren Newsletter an

Seien Sie mit der/die erste um über neue Veranstaltungen, Neuigkeiten und Produkte informiert zu werden!