5.7A Typ. At 1-ph L/N 220Vac, 1.2A* 250V=300W per channel, total 1200W 3.1A Typ. At 2-ph L1/L2 400Vac, 1.2A* 250V=300W per channel, total 1200W
Input Power (Standby Mode)
0.5W At 220Vac/50Hz, Dim OFF, in compliance with Erp(EU) 2019/2020
Efficiency at 100% load
95% Typ. At 1-ph L/N 220Vac, 1.2A* 250V=300W per channel, total 1200W 96% Typ. At 2-ph L1/L2 400Vac, 1.2A* 250V=300W per channel, total 1200W
Inrush Current
12A At 220Vac,50%Apk to 50%Apk time: <2 ms 20A At 400Vac,50%Apk to 50%Apk time: < 2ms
Charging Time
-
Power Factor at 100% load
0.99 Typ. At 1-ph L/N 220Vac, Full load 0.99 Typ. At 2-ph L1/L2 400Vac, Full load
Leakage Current
-
Nominal Current
-
Total Harmonic Distortion
6% Typ. At 1-ph L/N 220Vac, total Pout=1200W Load 12% At 2-ph L1/L2 400Vac, total Pout=1200W Load
Power Dissipation
-
Efficiency @ 10% load
-
Input Voltage Phase
-
Case Chassis / Cover
Aluminum case, dark gray, compliance with C5 environment (ISO 9223)
Indicator
-
Cooling System
Natural Convection
Input Terminal
With the sign of L1, L2, PE
Output Terminal
With the sign of PE, NTC, V+, V4-, V3-, V2-, V1-
Signal Terminal
-
Noise Sound Pressure Level (SPL)
< 24dBA
Input/Output Terminal
-
Signal
-
Mounting Rail
-
Wire
-
Protection Structure
-
Terminal
-
Unit Weight
5.1 kg (11.24 lb)
Dimensions
500 x 152 x
77 mm 19.69” x
5.98” x
3.03”
Vibration (Operating)
-
Shock Test (Operating)
-
Operating Temperature
-40 ~+50°C
Storage Temperature
-40°C to +85°C
Power De-rating
-
Operating Humidity
10% to 90% RH (Non-Condensing)
Shock Test (Non-Operating)
-
Vibration (Non-Operating)
IEC 60068-2-6, Random: 5 Hz to 10 Hz (1G); 30 min per axis for all X, Y, Z direction
Storage Humidity
10% to 90% RH (Non-Condensing)
Operating Altitude
-
Pollution Degree
-
Bump Test (Operating)
-
Over Voltage Category
-
Corrosion
-
Shock
-
Vibration
-
Acoustic Noise
-
Overvoltage
-
Overload / Overcurrent
-
Over Temperature
-
Short Circuit
-
Reverse Polarity Protection
-
Degree of Protection
IP66 (EN 60529)
Protection Against Shock
-
Input Polarity Protection
-
Battery Polarity Protection
-
Wrong Battery Voltage Protection
-
Deep Discharge Protection
-
Overload
-
Overcurrent
-
Internal Fuse
-
Insufficient Input Voltage Protection
-
MTBF
475khrs. at Ta=+45°C Telcordia SR-332
Expected Cap Life Time
50,000 hours applicable for 220Vac to 480Vac(50/60Hz)@100% of load, Ta=50°C (Tcase=80°C)
Safety Certificate
ENEC: EN 61347-1:2015, EN 61347-1:2015/A1:2021 EN 61347-2-13:2014, EN 61347-2-13/A1:2017 IEC/EN 62384:2020 CB: EN 61347-1:2015, EN 61347-1:2015/A1:2021 EN 61347-2-13:2014, EN 61347-2-13/A1:2017 RCM: AS/NZS 61347-1: 2016+A1 AS 61347-2-13: 2018 UL: UL Compliant ANSI / UL8750 2nd Ed. CSA C22.2 No.250.13, 4th Ed. CCC Compliant: GB 19510.1 GB 19510.14 BIS Compliant: IS 15885(Part 2/Sec 13) KC Compliant: K 61347-1 K 61347-2-13 PSE Compliant: J 61347-1 J 61347-2-13
Electrical Safety
-
CE
CE Declaration of Conformity.
Medical Safety
-
Galvanic Isolation
-
Industrial Control Equipment
-
Hazardous Location / ATEX
-
II 3 G ATEX 2014/34/EU
-
Electrical Equipments of Machines
-
Electrical Equipment for Use in Electrical Power Installations
-
Safety Entry Low Voltage
-
Maritime
-
Material and Parts
-
Isolation Resistance
-
PE Resistance
-
UKCA
BS EN 61347-2-13: 2014+A1:2017
Certificates for Other Countries
-
BIS
-
KC
-
Electrical Equipment for Measurement, Control, and Laboratory Use
-
ITE Safety
-
SIL3
-
Emission
Radiated Emission: EN55015, GB/T17743, FCC Part 15, Subpart B Conducted Emission: EN55015, GB/T17743, FCC Part 15, Subpart B
Immunity
-
Harmonic Current Emissions
IEC/EN 61000-3-2, GB 17625.1
Voltage Fluctuation and Flicker
IEC/EN 61000-3-3
ESD Immunity
IEC/EN 61000-4-2
Radiated Immunity
-
EFT
IEC/EN 61000-4-4
Surge
(AC Mains) IEC/EN 61000-4-5 - Common Mode: 10kV (L1 to Earth, L2 to Earth) - Differential Mode: 10kV (L1 to L2)
Be the first to hear about new events, news and products!
Subscribe to our newsletter
Be the first to hear about new events, news and products!
Subscribe
Subscribe to DeltaPSU newsletter and be the first to know about our new product releases and industry knowledge. Read our Privacy Policy.
Marketing Permissions*
DeltaPSU will use the information you provide on this form to be in touch with you.
To unsubscribe, click the link in our newsletter. We will treat your data with respect.
We use cookies to provide the best user experience for those who visit our website. By using this website you agree to the placement of cookies and our Privacy Policy. Accept