IEC 60068-2-6, 10Hz to 150Hz @ 25m/S? (2.5G peak); displacement of 0.35mm; 90 min per axis for all X, Y, Z direction
Shock Test (Operating)
-
Operating Temperature
-10°C to +70°C
Storage Temperature
-40°C to +85°C
Power De-rating
Temperature: > 50°C de-rate power by 2.5% / °C Input Voltage: < 90Vac de-rate power by 2.0% / °C
Operating Humidity
5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)
IEC 60068-2-27, Half Sine 50G for a duration of 11ms, 3 times per direction, 9 times in total
Vibration (Non-Operating)
-
Storage Humidity
-
Operating Altitude
0 to 5,000 Meters (16,400 ft.)
Pollution Degree
2
Bump Test (Operating)
-
Over Voltage Category
II
Corrosion
-
Overvoltage
V1: < 36V, SELV Output, Latch Mode VSB: < 19V, SELV Output, Hiccup Mode, Non-Latching (Auto-Recovery)
Overload / Overcurrent
Hiccup Mode, Non-Latching (Auto-Recovery) - V1: Range of 7.5-8.8A, when VSB is operating at rated output current. Protects only V1 and VSB continues operate - VSB: Range of 0.6-1.1A, when V1 is operating at rated output current. Protects only VSB an
Over Temperature
< 75°C Surrounding Air Temperature @ 100% load, Only V1 shuts down in Latch Mode, VSB continuous to operate
Short Circuit
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) - V1: short circuit, VSB: still continuously operating - V1: still continuously operating, VSB: short circuit
Reverse Polarity Protection
-
Degree of Protection
-
Protection Against Shock
Class I with PE connection
Input Polarity Protection
-
Battery Polarity Protection
-
Wrong Battery Voltage Protection
-
Deep Discharge Protection
-
Overload
-
Overcurrent
-
Internal Fuse
-
Insufficient Input Voltage Protection
-
MTBF
> 700,000 hrs. as per Telcordia SR-332 I/P: 115Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time
10 years (115Vac & 230Vac, 50% load @ 40°C)
Safety Certificate
-
Electrical Safety
TUV Bauart: EN 60950-1, EN 62368-1 UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme: IEC 60950-1, IEC 62368-1
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Medical Safety
-
Galvanic Isolation
Input to Output: 3.0KVac Input to FG: 1.5KVac Output to FG: 0.5KVac
Industrial Control Equipment
-
Hazardous Location / ATEX
-
II 3 G ATEX 2014/34/EU
-
Electrical Equipments of Machines
-
Electrical Equipment for Use in Electrical Power Installations
-
Safety Entry Low Voltage
SELV (IEC 60950-1)
Maritime
-
Material and Parts
-
Isolation Resistance
-
PE Resistance
-
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and The Electromagnetic Compatibility Regulations 2016 No. 1091
Certificates for Other Countries
-
BIS
-
KC
-
Electrical Equipment for Measurement, Control, and Laboratory Use
-
ITE Safety
-
SIL3
-
Emission
Generic Standards: CISPR 22, CISPR 32, EN/BS EN 55022, EN/BS EN 55032, FCC Title 47: Class B
Yeni etkinlikleri, haberleri ve ürünleri ilk duyan siz olun!
Bültenimize abone olun
Yeni etkinlikleri, haberleri ve ürünleri ilk duyan siz olun!
Abone Ol
DeltaPSU bültenine abone olarak yeni ürünleri ve endüstri bilgilerini ilk öğrenen siz olun. Okuyun: Gizlilik Politikası.
Pazarlama İzinleri*
DeltaPSU sizinle temasa geçmek için bu formda verdiğiniz bilgileri kullanacaktır.
Aboneliği sonlandırmak için bültenimizdeki bağlantıya tıklayın.
İnternet sitemizi ziyaret edenlerin en iyi kullanıcı deneyimini yaşaması için çerezleri kullanıyoruz. Bu internet sitesini ziyaret ederek çerezleri kullanmayı kabul etmiş olursunuz. Gizlilik Politikası. Kabul et