Linear power derate from 100% load at 50°C, to 50% load at 70°C
運行濕度
5-95% RH (Non-Condensing)
衝擊測試(非運行狀態)
50G, 11ms, 3 shocks for each direction
振動測試(非運行狀態)
-
儲藏濕度
-
運行高度
Up to 5,000 meters (up to 16,400 feet or 106-54kPa)
污染程度
-
碰撞試驗(運行狀態)
-
過壓類別
-
Corrosion
-
過壓保護
(max) Main output 140% of rated normal voltage, Latch Mode Standby 125% of rated voltage, Latch Mode
超負載/過電保護
(max) Main output 160% of rated current Standby 2A max Hiccup Mode(Non-Latching, Auto-Recovery) Fan Output 1.5A max with current limiting protection
過溫保護
Latch Mode for Main output
短路保護
Hiccup Mode, (Non-Latching, Auto-Recovery)
極性反接保護
-
防護等級
-
電擊防護等級
-
輸入端極性保護
-
電池極性保護
-
電池電壓保護錯誤
-
深度放電保護
-
超負載保護
-
過電保護
-
內部保險絲
-
Insufficient Input Voltage Protection
-
MTBF
(Minimum) at 115Vac, Full Load, 35 °C 500 Khrs based on Telecordia SR-332
預計最長使用壽命
-
Safety Certificate
IEC 60601-1 CB report TUV EN 60601-1 A11/A12 UL 60601-1+CAN/CSA 60601-1 IEC 60950-1, IEC 62368-1 CB report TUV EN 60950-1, EN 62368-1 UL 60950-1+CAN/CSA 60950-1, UL 62368-1+CAN/CSA 62368-1
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU EN 60601-1: 2006 + A11: 2011 + A1: 2013 + A12: 2014 & EN 60601-1-2: 2015
醫療安全
IEC 60601-1 CB report TUV EN60601-1 UL 60601-1+CAN/CSA 60601-1
In conformance with Electrical Equipment (Safety) Regulations 2016, and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002(UK MDR 2002)
國家地區證書
-
BIS
-
KC
-
Electrical Equipment for Measurement, Control, and Laboratory Use